Without VAT | With VAT | |
---|---|---|
Base Price: | €26.716,50 | €32.326,97 |
Total: | €26.716,50 | €32.326,97 |
HP 12508 AC Switch Chassis
BGP | RFC 1657 Definitions of Managed Objects for BGPv4; RFC 1771 BGPv4; RFC 1772 Application of the BGP; RFC 1773 Experience with the BGP-4 Protocol; RFC 1774 BGP-4 Protocol Analysis; RFC 1997 BGP Communities Attribute; RFC 1998 PPP Gandalf FZA Compression Protocol; RFC 2385 BGP Session Protection via TCP MD5; RFC 2439 BGP Route Flap Damping; RFC 2796 BGP Route Reflection; RFC 2842 Capability Advertisement with BGP-4; RFC 2858 BGP-4 Multi-Protocol Extensions; RFC 2918 Route Refresh Capability |
Denial of service protection | RFC 2267 Network Ingress Filtering; Automatic Filtering of well known Denial of Service Packets; CPU DoS Protection; Rate Limiting by ACLs |
Device management | RFC 1155 Structure and Mgmt Information (SMIv1); RFC 1157 SNMPv1/v2c; RFC 1305 NTPv3; RFC 1945 Hypertext Transfer Protocol -- HTTP/1.0; RFC 2452 MIB for TCP6; RFC 2454 MIB for UDP6; RFC 2573 (SNMPv3 Applications); RFC 2578-2580 SMIv2; RFC 2579 (SMIv2 Text Conventions); RFC 2580 (SMIv2 Conformance); RFC 2819 (RMON groups Alarm, Event, History and Statistics only); RFC 2819 RMON; RFC 3417 (SNMP Transport Mappings); SNMP v3 and RMON RFC support; SSHv1/SSHv2 Secure Shell; TACACS/TACACS+ |
Differentiator | The HP 12508 Switch Chassis is an 8-slot AC-powered modular next-generation switching platform that delivers the scalablity and performance needed in the data center. |
ECO quick links bullet 01 URL | http://www.hp.com/hpinfo/globalcitizenship/environment/recycling/unwanted-hardware.html |
ECO quick links bullet 01 URL statement | Recycling and Reuse Options |
ECO quick links bullet 02 URL | http://h71028.www7.hp.com/enterprise/us/en/solutions/hp-carbon-footprint-calculator.html?jumpid=re_r138_eco_home_carbon_footprint_learn_more |
ECO quick links bullet 02 URL statement | Carbon Footprint Calculator |
ECO quick links bullet 03 URL | http://hp.com/environment |
ECO quick links bullet 03 URL statement | HP & the Environment |
Electromagnetic compatibility | VCCI Class A; EN 55022 Class A; VCCI V-3/2000.04; ICES-003 Class A; AS/NZS CISPR 22 Class A; EMC Directive 2004/108/EC; FCC (CFR 47, Part 15) Class A |
Form factor | 22U height |
General protocols | IEEE 802.1ad Q-in-Q; IEEE 802.1ag Service Layer OAM; IEEE 802.1ah Provider Backbone Bridges; IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.1X PAE; IEEE 802.3ab 1000BASE-T; IEEE 802.3ad Link Aggregation (LAG); IEEE 802.3ae 10-Gigabit Ethernet; IEEE 802.3ah Ethernet in First Mile over Point to Point Fiber - EFMF; IEEE 802.3i 10BASE-T; IEEE 802.3u 100BASE-X; IEEE 802.3x Flow Control; IEEE 802.3z 1000BASE-X; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 791 IP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 903 RARP; RFC 951 BOOTP; RFC 959 File Transfer Protocol (FTP); RFC 1027 Proxy ARP; RFC 1042 IP Datagrams; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 1812 IPv4 Routing; RFC 2131 DHCP; RFC 2338 VRRP; RFC 2784 Generic Routing Encapsulation (GRE); RFC 2865 Remote Authentication Dial In User Service (RADIUS) |
Headline | Compartmentalization |
Headline | Enterprise Resiliency and High Availability |
Headline | High-performance Networking Density with 1/10/40 & 100 GbE Connectivity |
Headline | Industry Leading Large Scalability for Enterprise Data Center Cores |
Headline | Layer 2 switching |
Headline | Layer 3 routing |
Heat dissipation | 14587 BTU/hr (15389.29 kJ/hr) |
IKEv1 | RFC 2865 - Remote Authentication Dial In User Service (RADIUS) |
Image legal disclaimer | Product image may differ from actual product |
Immunity standard | ETSI EN 300 386 V1.3.3; EN 55024:1998+ A1:2001 + A2:2003; EN 61000-4-2; IEC61000-4-2; EN 61000-4-3; IEC61000-4-3; EN 61000-4-4; IEC61000-4-4; EN 61000-4-5; IEC61000-4-5; EN 61000-4-6; IEC61000-4-6; IEC 61000-4-8; EN61000-4-8; EN 61000-4-11; IEC61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3 |
Input frequency | 50/60 Hz |
Input voltage | 100 - 120 / 200 - 240 VAC |
IP Multicast | RFC 1112 IGMP; RFC 2236 IGMPv2; RFC 2283 Multiprotocol Extensions for BGP-4; RFC 2362 PIM Sparse Mode; RFC 2934 Protocol Independent Multicast MIB for IPv4; RFC 3376 IGMPv3; RFC 3618 Multicast Source Discovery Protocol (MSDP); RFC 4601 PIM Sparse Mode |
IPv6 | RFC 1350 TFTP; RFC 1981 IPv6 Path MTU Discovery; RFC 2080 RIPng for IPv6; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2473 Generic Packet Tunneling in IPv6; RFC 2475 IPv6 DiffServ Architecture; RFC 2529 Transmission of IPv6 Packets over IPv4; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2740 OSPFv3 for IPv6; RFC 2893 Transition Mechanisms for IPv6 Hosts and Routers; RFC 2925 Definitions of Managed Objects for Remote Ping, Traceroute, and Lookup Operations (Ping only); RFC 3315 DHCPv6 (client only); RFC 3484 Default Address Selection for IPv6 ; RFC 3513 IPv6 Addressing Architecture; RFC 3587 IPv6 Global Unicast Address Format; RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4541 IGMP & MLD Snooping Switch; RFC 4862 IPv6 Stateless Address Auto-configuration |
Key selling point | Bridge Protocol Data Unit (BPDU) tunneling: transmits Spanning Tree Protocol BPDUs transparently, allowing correct tree calculations across service providers, WANs, or MANs |
Key selling point | Department protection: using network virtualization standards (QinQ, VRF, and MPLS), the 12500 switch series allows organizations to isolate different business units with different resources (VRFs); using standard-based mechanisms, the network is completely virtualized, reducing cost and operations |
Key selling point | Enhanced Multitenant Device Context (MDC) for multi-tenancy giving you the ability to virtualize a physical switch into multiple logical devices; each logical switch has its own tenants. |
Key selling point | Equal-Cost Multipath (ECMP): enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth |
Key selling point | Ethernet Virtual Interconnect for (EVI) is a virtual application network solution that provides a Layer2 extension across the data center to simplify the interconnectivity of geographically dispersed data centers. |
Key selling point | GARP VLAN Registration Protocol: allows automatic learning and dynamic assignment of VLANs |
Key selling point | High-performance fully distributed architecture delivers up to 24.3 Tb/s switching capacity. |
Key selling point | Hot-swappable and redundant fans and power supplies increase the reliability of the switch while lowering data center energy costs. |
Key selling point | IEEE 802.1ad QinQ: increases the scalability of an Ethernet network by providing a hierarchical structure; connects multiple LANs on a high-speed campus or metro network |
Key selling point<
No options for this product
Every effort has been made to ensure the accuracy of all information contained herein. e-nitiative shall not be liable for any changes resulting in wrong product description, tax code and/or price. The shown information (specifications, prices, taxes) should be considered as an indication and can be changed at any moment and without any prior notice.
Cookie Policy
Functional cookiesThese cookies ensure that the webstore functions properly. Think of keeping track of your language and your products in your shopping basket, log on with your account, the checkout form, filter search results etc. Other cookiesWe use analytical and tracking cookies to see how we can improve the webstore and how we can adapt content and potential advertisements to your preference. |